Flow Measurement
Showing 73–96 of 239 results
-
Flow Measurement
G2P10NQ9GMA 1″
View1″ NPT Female PVDFRate & Totals G2 Series – INDUSTRIAL GRADE METER – FOR AGGRESSIVE CHEMICALSMain SpecificationsConnection Size: 1″Connection Type: NPT FemaleFlow Range: 5 – 50 GPM (18.9 – 190 LPM)Pressure Rating: 100 PSI (6.8 Bar)Operating Temp With Local Computer:0 to 140°F (-18 to 60°C) for SAFE AREA (Non-FM Approved)0 to 129°F (-18 to 54°C) for INTRINSICALLY SAFE (FM Approved) -
Flow Measurement
G2S – Flanged 316SS
ViewG2S10FQ9GMDFlanged 316SS Industrial Grade Electronic MeterMain SpecificationsConnection Size: 1"Connection Type: 150 lb ANSI FlangeFlow Range: 5 - 50 GPM (18.9 - 190 LPM)Pressure Rating: 255 PSI @ 140°F, 275 PSI @ 100°FOperating Temp With Local Computer:0 to 140°F (-18 to 60°C) for SAFE AREA (Non-FM Approved)0 to 129°F (-18 to 54°C) for INTRINSICALLY SAFE (FM Approved)Product AttachmentsINSTRUCTION MANUAL | DATASHEET | METER MANUAL -
Flow Measurement
G2S -Tri Clamp 316SS
ViewG2S05TQ9GMATri-Clamp 316SS Industrial Grade Electronic MeterMain SpecificationsConnection Type: Tri-ClampFlow Range: 1 - 10 GPM (3.8 - 37.9 LPM)Pressure Rating: 150 PSI (10.2 Bar)Connection Size: 3/4" (1/2" Meter Body Size)Operating Temp With Local Computer:0 to 140°F (-18 to 60°C) for SAFE AREA (Non-FM Approved)0 to 129°F (-18 to 54°C) for INTRINSICALLY SAFE (FM Approved)Product AttachmentsINSTRUCTION MANUAL | DATASHEET | METER MANUAL -
Flow Measurement
G2S05NQ9GMA (1/2″)
View1/2″ NPT Female 316SSRate & Totals G2 Series – INDUSTRIAL GRADE METERMain SpecificationsConnection Size: 1/2″Connection Type: NPT FemaleFlow Range: 1 – 10 GPM (3.8 – 37.9 LPM)Pressure Rating: 1500 PSI (102 Bar)Operating Temp With Local Computer:0 to 140°F (-18 to 60°C) for SAFE AREA (Non-FM Approved)0 to 129°F (-18 to 54°C) for INTRINSICALLY SAFE (FM Approved) -
Flow Measurement
G2S05TQ9GMA (3/4″)
View3/4″ (1/2″ Meter Body Size) Tri-Clamp 316SSRate & Totals G2 Series – INDUSTRIAL GRADE METERMain SpecificationsConnection Type: Tri-ClampFlow Range: 1 – 10 GPM (3.8 – 37.9 LPM)Pressure Rating: 150 PSI (10.2 Bar)Connection Size: 3/4″ (1/2″ Meter Body Size)Operating Temp With Local Computer:0 to 140°F (-18 to 60°C) for SAFE AREA (Non-FM Approved)0 to 129°F (-18 to 54°C) for INTRINSICALLY SAFE (FM Approved) -
Flow Measurement
G2S07NQ9GMA (3/4″)
View3/4″ NPT Female 316SSRate & Totals G2 Series – INDUSTRIAL GRADE METERMain SpecificationsConnection Size: 3/4″Connection Type: NPT FemaleFlow Range: 2 – 20 GPM (7.6 – 75.7 LPM)Pressure Rating: 1500 PSI (102 Bar)Operating Temp With Local Computer:0 to 140°F (-18 to 60°C) for SAFE AREA (Non-FM Approved)0 to 129°F (-18 to 54°C) for INTRINSICALLY SAFE (FM Approved) -
Flow Measurement
G2S07TQ9GMA 1″
View1″ (3/4″ Meter Body Size) Tri-Clamp 316SSRate & Totals G2 Series – INDUSTRIAL GRADE METERMain SpecificationsConnection Type: Tri-ClampFlow Range: 2 – 20 GPM (7.6 – 75.7 LPM)Pressure Rating: 150 PSI (10.2 Bar)Connection Size: 1″ (3/4″ Meter Body Size)Operating Temp With Local Computer:0 to 140°F (-18 to 60°C) for SAFE AREA (Non-FM Approved)0 to 129°F (-18 to 54°C) for INTRINSICALLY SAFE (FM Approved) -
Flow Measurement
G2S10FQ9GMD (1″)
View1″ 150 lb ANSI Flange 316SSRate & Totals G2 Series – INDUSTRIAL GRADE METERMain SpecificationsConnection Size: 1″Connection Type: 150 lb ANSI FlangeFlow Range: 5 – 50 GPM (18.9 – 190 LPM)Pressure Rating: 255 PSI @ 140°F, 275 PSI @ 100°FOperating Temp With Local Computer:0 to 140°F (-18 to 60°C) for SAFE AREA (Non-FM Approved)0 to 129°F (-18 to 54°C) for INTRINSICALLY SAFE (FM Approved) -
Flow Measurement
G2S10NQ9GMA 1″
View1″ NPT Female 316SSRate & Totals G2 Series – INDUSTRIAL GRADE METERMain SpecificationsConnection Size: 1″Connection Type: NPT FemaleFlow Range: 5 – 50 GPM (18.9 – 190 LPM)Pressure Rating: 1500 PSI (102 Bar)Operating Temp With Local Computer:0 to 140°F (-18 to 60°C) for SAFE AREA (Non-FM Approved)0 to 129°F (-18 to 54°C) for INTRINSICALLY SAFE (FM Approved) -
Flow Measurement
G2S10TQ9GMA (1-1/2″)
View1-1/2″ (1″ Meter Body Size) Tri-Clamp 316SSRate & Totals G2 Series – INDUSTRIAL GRADE METERMain SpecificationsConnection Type: Tri-ClampFlow Range: 5 – 50 GPM (18.9 – 190 LPM)Pressure Rating: 150 PSI (10.2 Bar)Connection Size: 1-1/2″ (1″ Meter Body Size)Operating Temp With Local Computer:0 to 140°F (-18 to 60°C) for SAFE AREA (Non-FM Approved)0 to 129°F (-18 to 54°C) for INTRINSICALLY SAFE (FM Approved) -
Flow Measurement
G2S15FQ9GME (1-1/2″)
View1-1/2″ 150 lb ANSI Flange 316SSRate & Totals G2 Series – INDUSTRIAL GRADE METERMain SpecificationsConnection Size: 1-1/2″Connection Type: 150 lb ANSI FlangeFlow Range: 10 – 100 GPM (38.0 – 380 LPM)Pressure Rating: 255 PSI @ 140°F, 275 PSI @ 100°FOperating Temp With Local Computer:0 to 140°F (-18 to 60°C) for SAFE AREA (Non-FM Approved)0 to 129°F (-18 to 54°C) for INTRINSICALLY SAFE (FM Approved) -
Flow Measurement
G2S15NQ9GMB (1-1/2″)
View1-1/2″ NPT Female 316SSRate & Totals G2 Series – INDUSTRIAL GRADE METERMain SpecificationsConnection Size: 1-1/2″Connection Type: NPT FemaleFlow Range: 10 – 100 GPM (38.0 – 380 LPM)Pressure Rating: 1500 PSI (102 Bar)Operating Temp With Local Computer:0 to 140°F (-18 to 60°C) for SAFE AREA (Non-FM Approved)0 to 129°F (-18 to 54°C) for INTRINSICALLY SAFE (FM Approved) -
Flow Measurement
G2S15TQ9GMB (2″)
View2″ (1-1/2″ Meter Body Size) Tri-Clamp 316SSRate & Totals G2 Series – INDUSTRIAL GRADE METERMain SpecificationsConnection Type: Tri-ClampFlow Range: 10 – 100 GPM (38.0 – 380 LPM)Pressure Rating: 150 PSI (10.2 Bar)Connection Size: 2″ (1-1/2″ Meter Body Size)Operating Temp With Local Computer:0 to 140°F (-18 to 60°C) for SAFE AREA (Non-FM Approved)0 to 129°F (-18 to 54°C) for INTRINSICALLY SAFE (FM Approved) -
Flow Measurement
G2S20FQ9GME (2″)
View2″ 150 lb ANSI Flange 316SSRate & Totals G2 Series – INDUSTRIAL GRADE METERMain SpecificationsConnection Size: 2″Connection Type: 150 lb ANSI FlangeFlow Range: 20 – 200 GPM (76 – 760 LPM)Pressure Rating: 255 PSI @ 140°F, 275 PSI @ 100°FOperating Temp With Local Computer:0 to 140°F (-18 to 60°C) for SAFE AREA (Non-FM Approved)0 to 129°F (-18 to 54°C) for INTRINSICALLY SAFE (FM Approved) -
Flow Measurement
G2S20NQ9GMB 2″
View2″ NPT Female 316SSRate & Totals G2 Series – INDUSTRIAL GRADE METERMain SpecificationsConnection Size: 2″Connection Type: NPT FemaleFlow Range: 20 – 200 GPM (76 – 760 LPM)Pressure Rating: 1500 PSI (102 Bar)Operating Temp With Local Computer:0 to 140°F (-18 to 60°C) for SAFE AREA (Non-FM Approved)0 to 129°F (-18 to 54°C) for INTRINSICALLY SAFE (FM Approved) -
Flow Measurement
G2S20TQ9GMB (2-1/2″)
View2-1/2″ (2″ Meter Body Size) Tri-Clamp 316SSRate & Totals G2 Series – INDUSTRIAL GRADE METERMain SpecificationsConnection Type: Tri-ClampFlow Range: 20 – 200 GPM (76 – 760 LPM)Pressure Rating: 150 PSI (10.2 Bar)Connection Size: 2-1/2″ (2″ Meter Body Size)Operating Temp With Local Computer:0 to 140°F (-18 to 60°C) for SAFE AREA (Non-FM Approved)0 to 129°F (-18 to 54°C) for INTRINSICALLY SAFE (FM Approved) -
Flow Measurement
High Temperature
ViewLZ series variable-area flow meter with metallic tube has the characteristics of simplicity, reliability wide application field, high precision and easy installation. -
Flow Measurement
IFX-A
ViewUltrasonic flow meter IFX-A ISOFLUXThe ISOFLUX IFX-A ultrasonic flow meter is suitable for applications on clean water and low conductivity liquids.It belongs to a complete range of flow meters ISOFLUX, intended for flow measurements of conductive, non-conductive liquids, the range includes the following versions:IFX-A – AC mains powered meters (in this product sheet)IFX-B – Battery powered metersIFX-R – MID certified battery water metersUltrasonic flow meters operate on transit time principle by measuring the time difference of ultrasonic waves traveling in and against the direction of the fluid flow. -
Flow Measurement
IFX-B
ViewUltrasonic flow meter IFX-B ISOFLUXThe ISOFLUX IFX-B ultrasonic flow meter is suitable for applications on clean water and low conductivity liquids.It belongs to a complete range of flow meters ISOFLUX, intended for flow measurements of conductive, non-conductive liquids, the range includes the following versions:IFX-A – AC mains powered metersIFX-B – Battery powered metersIFX-R – MID certified battery water metersUltrasonic flow meters operate on transit time principle by measuring the time difference of ultrasonic waves traveling in and against the direction of the fluid flow. -
Flow Measurement
IFX-F100
ViewUltrasonic flow meter clamp-on for fixed installation IFX-F100The IFX-F100 clamp-on ultrasonic flow meter for fixed installations, for pipes of various materials and for pipes from DN10 to DN3000.Since clamp-on technology is not intrusive, this is suitable for measuring any fluid regardless of conductivity, pressure or chemical characteristics; the IFX-F100 clamp-on ultrasonic flow meter is equipped with a backlit LCD display and a 5-key keyboard for programming.Through its simple and intuitive menu with installation support function, for quick and easy commissioning, it allows correct positioning of the sensors.The measurement principle is based on transit time with DSP technology for greater precision and offers a bidirectional measurement with totalization function.It has digital or analogue outputs including Modbus, RTU and HART as well as analogue input and input of PT100 temperature sensors thanks to the PT100 temperature inputs the instrument is also able to measure thermal energy.The instrument is also equipped with a large data logger for storing up to 1,000,000 data in 100,000 records. -
Flow Measurement
IFX-P200
ViewPortable Clamp-On Flow Meter IPX-P200The IFX-P200 clamp-on portable ultrasonic flow meter is perfect for short-term flow measurement campaigns.It is suitable for the measurement of any type of fluid, regardless of conductivity, pressure or chemical characteristics or that allows the transmission of the sound wave, as well as on pipes of different materials.The instrument is equipped with a display for showing the instantaneous flow rate and the totalized volume, a large data logger to store up to 1,000,000 data (in 100,000 records) and dedicated software for data management, with a simple and intuitive menu also as an installation support function, for quick and easy commissioning. -
Flow Measurement
IFX-P210
ViewPortable ultrasonic clamp-on flow meter IFX-P210 ISOFLUXThe portable clamp-on flow meter IFX-P210 is available in single or double-string is ideal for a wide range of applications, from water network for leak detection or district in the network, to temporary replacement of inline flow meters, or for industrial applications on corrosive or dangerous fluids.Battery-powered is a quick and easy tool to install with non-invasive snsors with a transit time-based measurement principle.The installation of the sensors is guided by software, for easy identification of the correct location.The IFX-P210 clamp-on range meter can be used on DN10 to DN3000 and DN 50 to DN 3000 with a single pair of sensors. It features a large, integrated logger that stores up to 1,000,000 data and data download software.In addition, the IFX-P210 clamp-on range meter is contained in a robust and sealable IP67 case for measurement and instrument safety.The tool can also be equipped with a wide range of incoming and outgoing signals as well as communication protocols such as the Modbus. -
Flow Measurement
IFX-R
ViewUltrasonic flow meter IFX-R ISOFLUXThe ISOFLUX IFX-R ultrasonic flow meter is MID MI001 certified for application on drinking water. The instrument is based on the ultrasonic measuring principle with transit time and is available for diameters from 50 mm up to 200mm.It is a double beam version without the use of mirrors or similar, really full bore design, with neglectable pressure drops.The IFX-R meter has an R 500 Q3/Q1 ratio, the capability to be installed in any position, both vertical and horizontal and does not require any straight pipe lengths for installation, as it is U0 / D0 certified.Powered by lithium batteries for a life of more than 10 years of operation, include a powerful integrated data logger and on request can be equipped with pulse outputs or communication via radio with dedicated protocols such as SigFox or Lora.It belongs to a complete range of flow meters ISOFLUX, intended for flow measurements of conductive, non-conductive liquids, the range includes the following versions:IFX-A – AC mains powered metersIFX-B – Battery powered metersIFX-R – MID certified battery water metersUltrasonic flow meters operate on transit time principle by measuring the time difference of ultrasonic waves traveling in and against the direction of the fluid flow.