G2P10NQ9GMA 1″

, , , ,

1″ NPT Female PVDF

Rate & Totals G2 Series – INDUSTRIAL GRADE METER – FOR AGGRESSIVE CHEMICALS

Main Specifications

Connection Size: 1″

Connection Type: NPT Female

Flow Range: 5 – 50 GPM (18.9 – 190 LPM)

Pressure Rating: 100 PSI (6.8 Bar)

Operating Temp With Local Computer:
0 to 140°F (-18 to 60°C) for SAFE AREA (Non-FM Approved)
0 to 129°F (-18 to 54°C) for INTRINSICALLY SAFE (FM Approved)

Download Documents

  • Meter Body Size: 1″
  • Local/Remote Display: Local
  • Display Type: Digital LCD
  • Factory Calibrated For: Water like fluids
  • Flow Meter Type: G2 Series – INDUSTRIAL GRADE METER – FOR AGGRESSIVE CHEMICALS
  • Std Calibration Reports Included: Yes
  • Application/Flow: Call concerning DI Water applications
  • Warranty Period: 1 Year
  • Product Type: Rate & Totals
  • Benefits & Features: Can Handle Aggressive Chemicals; Accurate; 2-Year Battery Powered; 6 Digit Display – Floating Decimal; Rate of Flow; Batch & Cumulative Totals; Factory Calibrated and Field Calibratable; Add-On Output Options; FM Approved Class I, Div. I; Replaceable Internal Meter Body Parts; Choice of Gallons or Liters; Custom Programmable Display (including UOM)
  • Max Pressure Drop (at Max Flow in test conditions): 6.5 PSI
  • Accuracy (% of Reading) Factory Calibrated with Computer: ± 1.0%
  • Accuracy (% of Reading) Factory Calibrated Body Only: ± 1.5%
  • Repeatability (based on test conditions): ± 0.3%
  • Recommended Strainer Size: 35 Mesh (500 Microns)
  • Max. Particle Size: .018″ / .457 mm
  • Operating Temp Without Local Computer or With Remote Computer: -20 to 180°F (-28 to 82°C)[Opt’l]
  • Extended Flow Range: 50 – 75 GPM (190 – 284 LPM)<br>[Accuracy of the extended flow range
  • declines and is not guaranteed]<br>Overranging damages meter and voids warranty
  • Maximum Viscosity: 100 cps<br>[For viscous fluids like oils, the temperature must not fluctuate more than ±5°F to avoid accuracy fluctuations]
  • Applications (always check Chemical Compatibility Guide): Bleach, Phosphoric Acid, Some Sulfuric Acid Concentrations, Ferric Chloride, Phenol, DI Water rated < 12 M-Ohms
  • Not Suitable For Applications: Oils, especially those heavier than 10W (100cps), Fluctuating viscosities**
  • Minimum Straight Pipe Dia.s: 10″ Upstream / 5″ Downstream
  • Desired Straight Pipe Dia.s: 20″ Upstream / 10″ Downstream
  • Application Notes: Unidirectional but Display can be rotated 180°, Can mount Horizontally or Vertically, Can use for Gravity Feeds, Line should be kept full (no air) for proper accuracy
  • Piping Notes: If cavitation affects accuracy, try a flow control valve downstream of meter