Ultrasonic Level Transmitter
จำหน่าย Ultrasonic Level Transmitter เครื่องวัดระดับแบบไม่สัมผัส เหมาะสำหรับวัดระดับน้ำ ของเหลว และสารเคมี ติดตั้งง่าย แม่นยำสูง ใช้ในโรงงานอุตสาหกรรม
Showing all 8 results
-
Level Measurement
DLT 2.0
Read moreDifferential Level TransmitterThe DLT 2.0 Differential Level Transmitter is a simple solution for differential level measurement including applications found in wastewater treatment plants, pump stations, and combined sewer systems. The Differential Level Transmitter includes two differential level sensors. Position each sensor at your desired location, above a channel, up and downstream from a bar screen for example, and the DLT 2.0 can display and transmit differential level measurement. The downstream sensor could even be positioned above a flume or weir to measure and totalize open channel flow. -
Accessories
FlowCERT
Read moreNon-contacting Area Velocity Flow MonitorPulsar Measurement’s FlowCERT provides comprehensive open channel flow measurement with extensive data logging and control functions. It includes a range of pre-programmed flumes and weirs, so setup is quick, simple, and straightforward. The unit is compatible with a range of both contacting and non-contacting sensors and has the flexibility to change with your application. -
Doppler Flow Meter
MantaRay
Read morePortable Area Velocity Flow MeterThe MantaRay is a portable area velocity meter that measures flow using a submersible ultrasonic sensor. The unit is designed for flow surveys in open channels, partially-full sewer pipes, and surcharged pipes – making the portable open channel flow meter suitable for sewer monitoring, industrial flow monitoring, irrigation flow, and natural streams.Easy to UseThe MantaRay Portable Area-Velocity Flow Meter measures both level and velocity to calculate flow in an open channel or pipe. Calibration is simple: enter the pipe diameter or channel dimensions and the MantaRay automatically computes and displays the flow rate and total on its backlit LCD display.The ultrasonic sensor mounts inside the pipe or on the bottom of a channel with a stainless-steel mounting bracket (included) and a single screw into the bottom of the pipe or channel. No special compounds, tools, or hardware are required. The sensor is completely sealed with no orifices or ports, making it resistant to build-up and fouling. -
Ultrasonic Level Transmitter
OCF 6.1
Read moreOCF 6.1Non-Contacting Open Channel Flow MeterThe OCF 6.1 is an open channel flow meter that doubles as a tank level meter, making it a perfect solution for both non-contacting flow measurement and level measurement. The non-contacting open channel flow meter is able to continuously monitor, display, totalize, and data log flow through any flume or weir. The ultrasonic sensor supplied with the OCF 6.1 mounts just 203.2 mm (8 in) above the flowing water giving +/- 0.25% accuracy.This non-contacting open channel flow measurement device includes a built-in 26 million point data logger and flow reporting system. Use the isolated 4-20mA to transmit flow to remote chart recorders or displays, and the control relays are programmable for level/flow alarm and flow proportionate pulse (for samplers, chlorinators, or remote totalizers).Use the OCF 6.1 in open channel flow mode for non-invasive flow, irrigation flow monitoring, industrial flow monitoring, and influent and effluent flow.For tank level measurement, simply mount the ultrasonic sensor at the top of the tank and the separate, watertight electronics/display enclosure is mounted at a convenient nearby location within 152.4 m (500 ft) of the sensor. An intrinsic safety barrier is optional for sensor and cable installations in hazardous rated locations. Get accurate and reliable tank level measurement, stock control, and silo measurement without having to interrupt or shut down the process.Product AttachmentsBROCHURE | DATASHEET | INSTALLATION MANUAL -
Doppler Flow Meter
Stingray 2.0
Read morePortable Level Velocity LoggerThe Stingray 2.0 is a portable level-velocity logger, with free Logger Software for the calculation of flow as an open channel meter. The design is compact, portable, and battery-powered which makes it a fantastic instrument for open channel flow measurement. Using four standard Alkaline D-cell batteries to operate as a battery-powered data logger, the unit is a complete area velocity logger with an ultrasonic sensor that data logs level, velocity, and water temperature for flow monitoring through open channels, partially full sewer pipes and surcharged pipes. -
Accessories
Ultra 5
Read moreMulti-functional Controller with 5 relaysThe Ultra 5 offers pump control, flow measurement, level control, volume calculations, and differential level measurement all in one compact unit. The control unit provides five assignable relays with extra-alarm options such as pump efficiency and extra pump control functions such as pump run on, pump exercising, storm and aeration control, and differential level control; the addition of further relays in open channel flow applications. -
Accessories
UltraTWIN
Read moreTwin-channel, differential level measurementUltraTWIN offers twin-channel differential level and volume monitoring. Each channel is user-configurable to operate independently either as an open channel flow meter, a pump control system, or as a level and volume monitoring unit for liquids and solids. The wall-mount version of the UltraTWIN controller offers two screens, each programmed independently to be able to monitor differential level or for dual tank monitoring. Combine the UltraTWIN with the dB Ultrasonic Transducer Series to get an accurate and reliable level measurement of liquids or solids.