G2S20FQ9GME (2″)

, , , ,

2″ 150 lb ANSI Flange 316SS

Rate & Totals G2 Series – INDUSTRIAL GRADE METER

Main Specifications

Connection Size: 2″

Connection Type: 150 lb ANSI Flange

Flow Range: 20 – 200 GPM (76 – 760 LPM)

Pressure Rating: 255 PSI @ 140°F, 275 PSI @ 100°F

Operating Temp With Local Computer:
0 to 140°F (-18 to 60°C) for SAFE AREA (Non-FM Approved)
0 to 129°F (-18 to 54°C) for INTRINSICALLY SAFE (FM Approved)

Download Documents

  • Meter Body Size: 2″
  • Local/Remote Display: Local
  • Display Type: Digital LCD
  • Factory Calibrated For: Water like fluids
  • Flow Meter Type: G2 Series – INDUSTRIAL GRADE METER
  • Std Calibration Reports Included: Yes
  • Warranty Period: 1 Year
  • Product Type: Rate & Totals
  • Benefits & Features: Excellent Chemical Compatibility; Accurate; Durable; 2-Year Battery Powered; 6 Digit Display – Floating Decimal; Rate of Flow; Batch & Cumulative Totals; Factory Calibrated and Field Calibratable; Add-On Output Options; FM Approved Class I, Div. I; Replaceable Internal Meter Body Parts; Choice of Gallons or Liters; Custom Programmable Display (including UOM)
  • Max Pressure Drop (at Max Flow in test conditions): 4.7 PSI
  • Accuracy (% of Reading) Factory Calibrated with Computer: ± 0.75%
  • Accuracy (% of Reading) Factory Calibrated Body Only: ± 1.0%
  • Repeatability (based on test conditions): ± 0.1%
  • Recommended Strainer Size: 35 Mesh (500 Microns)
  • Max. Particle Size: .018″ / .457 mm
  • Operating Temp Without Local Computer or With Remote Computer: -40 to 250°F (-40 to 121°C) [Opt’l]
  • Extended Flow Range: 200 – 300 GPM (760 – 1136 LPM)<br>[Accuracy of the extended flow range declines and is not guaranteed]<br>Overranging damages meter and voids warranty
  • Maximum Viscosity: 100 cps<br>[For viscous fluids like oils, the temperature must not fluctuate more than ±5°F to avoid accuracy fluctuations]
  • Applications (always check Chemical Compatibility Guide): Water, Chemicals, Fuel Products
  • Not Suitable For Applications: DI Water; Oils, especially those heavier than 10W (100cps), Fluctuating viscosities**
  • Minimum Straight Pipe Dia.s: 20″ Upstream / 10″ Downstream
  • Desired Straight Pipe Dia.s: 40″ Upstream / 20″ Downstream
  • Application Notes: Unidirectional but Display can be rotated 180°, Can mount Horizontally or Vertically, Can use for Gravity Feeds, Line should be kept full (no air) for proper accuracy
  • Piping Notes: If cavitation affects accuracy, try a flow control valve downstream of meter

ต้องการใบเสนอราคา

Line add : @intech2000

Email : intech@intech2000.com

Phone : 02-440-1853

Scroll to Top