Operating at 125 kHz frequency the transducer provides high resolution and accuracy. Essential in open channel flow applications. The dBMACH3 can be used with the Ultra 4, 5 and TWIN when in open channel flow mode, or can be paired with the FlowCERT, all of which provide a typical accuracy of +/- 1 mm (0.039in). Resolution +/- 0.5 mm (0.019 in). Range 0 mm to 2.4 m (0 in to 7.9 ft).
- Zero effective blanking distance
- Specifically designed for non-contacting open channel flow
- 125 kHz frequency provides high resolution and accuracy
- Compatible with Ultra 4, 5, TWIN & FlowCERT
| General Specifications | |
|---|---|
| Spec: | Description: |
| Sensor Body Dimensions: | 180 mm D (sunshield) x 205 mm H (7.08 in x 8.1 in) |
| Weight: | Nominal 1.1 kg (2.4 lb) |
| Max & Min Temperature (Electronics): | Standard: -30 °C to +90 °C (-22 °F to +194 °F)
ATEX: -30 °C to +75 °C (-22 °F to +167 °F) |
| Measurement Range: | 0 mm to 2.4 m (0 in to 7.9 ft) |
| Accuracy: | ±1 mm (0.039 in) |
| Resolution: | ±0.5 mm (0.019 in) |
| Sensor Body Material: | Valox 357 U and syntactic foam face |
| Maximum Separation: | 500 m (1,640 ft) |
| Mounting Connection: | BSP or 1” NPT |
| ENVIRONMENTAL | |
| Enclosure Protection: | IP68 / NEMA 6P |
| APPROVALS | |
| CE Approval: | 2014/30/EU – EMC & 2014/34/EU ATEX Directives. Standards applied: EN 60079-0:2012+A11:2013/ EN 60079-11:2012 / EN 60079-18:2009 / EN 60079-26:2007 / EN 61326-1:2013 |
| ATEX Approval : | Standard ATEX EEx m II T6 or optional EEx ia IIC T6. FM/FMC approval. |
| PERFORMANCE | |
| Frequency: | 125 kHz |
| Beam Angle: | <10° |