ACF6000 Series

Mass flow meter

The ACF6000 Series uses the Coriolis effect as a technique for liquid mass flow measurement.
The ACF6000 can measure most of the liquids; the infrared light sensor makes it easy for you to set parameters & change the display data. The Double-C tube & Double-D Tube make it possible for the meter to be used in most liquid applications.

FEATURES

  • Can be programmed by an infrared light sensor without opening the cover
  • High turndown ratio of flow rate
  • It comes any flanges such as ANSI, DIN, JIS etc.
  • Excellent for high pressure application
  • Simple for installation, commission and maintenance
  • Self-diagnostic capabilities, cable faults, pipe vibration
  • High accuracy of +/-0.2% of reading (or +/-0.1% of reading)
  • With forward / reverse flow rate measurement function

PRODUCT ATTACHMENTS

DATASHEET

ติดต่อขอรายละเอียดหรือสนใจสินค้า

  • Line : @intech2000
  • Email : intech@intech2000.com
  • Tel : 02-440-1853
Category: Brand:

GENERAL SPECIFICATIONS

Sensor Type : C tube(15-40 mm)/U tube(40L-250 mm)
Size : 15-250 mm (1/2″-10″)
Flow Range : 0-240 kg/hr~0-2200 t/hr
Accuracy : +/-0.2% +/-ZS of reading (Standard)
: +/-0.1% +/-ZS of reading (Optional)
Repeatability : +/-0.03% +/-ZS of reading
Density Range : 200-2300 kgf/m3 (0.2-2.3 g/cm3)
Accuracy : +/-0.002 g/cm3
Temperature Range : -40~125 °C (Standard)
: -40~350 °C (Optional, Remote Only)
Material
Wetted Parts : Stainless Steel 316L
Flange : Stainless Steel 316L
Sensor Housing : Stainless Steel 304
Junction Box : Aluminum Alloy (Epoxy Paint)
Process Connection : Flange
Flange Type : JIS 10K / JIS 20K / JIS 40K
: ANSI 150# / ANSI 300# / ANSI 600#
: DIN PN10 / PN16 / PN25 / PN40
Protection Class : IP67
: Explosion Proof, Ex d e [ib] IIC T6 (Optional)
Installation : Compact or Remote
Signal Cable Length : 10-100 m
Display : 2 lines LCD with illumination
Flow Rate Unit : g/s, kg/m, kg/hr, t/hr, lb/m, USgal/m (6 Digit)
Density Unit : kg/m3, g/cm3 (6 Digit)
Totalizer Unit : g, kg, Ton, L, m3, Nm3, lb, USgal (7 Digit)
Temperature : °C, °F (4 Digit)
Keypad : Infrared light Sensor, can be programmed
without opening the cover
Turndown Ratio : 20:1
Damping : 0.01-1.0 Seconds
Low Flow Cutoff : 0.0-9.0%
Communication : RS485 (Modbus Protocol) (Standard)
: HART Signal (Optional)
Current Output : 4-20 mA (Isolated)
Load : Max. 750 Ω
Output Unit : Mass / Volume / Density / Temperature
Pulse Output : Open Collector
Rating : 3-30 VDC, 50 mA Max.
Alarm Output : Open Collector (Optional)
Power Supply : 90-260 VAC, 50/60 Hz or 24 VDC +/-10%
Power Consumption : 30-40 W (Depend on sensor size)
Cable Entry : Sensor to Converter-3/4″ G
: Signal output / Power supply-M20
Ambient Temperature : -40~60 °C
Max. Pressure : 63 kgf/cm2