G2S10FQ9GMD

Flanged 316SS Industrial Grade Electronic Meter

 

Main Specifications
Connection Size: 1″
Connection Type: 150 lb ANSI Flange
Flow Range: 5 – 50 GPM (18.9 – 190 LPM)
Pressure Rating: 255 PSI @ 140°F, 275 PSI @ 100°F
Operating Temp With Local Computer:
0 to 140°F (-18 to 60°C) for SAFE AREA (Non-FM Approved)
0 to 129°F (-18 to 54°C) for INTRINSICALLY SAFE (FM Approved)

Product Attachments

INSTRUCTION MANUAL | DATASHEET | METER MANUAL

Specification 

  • Max Pressure Drop (at Max Flow in test conditions): 9.7 PSI
  • Accuracy (% of Reading) Factory Calibrated with Computer: ± 1.0%
  • Accuracy (% of Reading) Factory Calibrated Body Only: ± 1.5%
  • Repeatability (based on test conditions): ± 0.1%
  • Recommended Strainer Size: 120 Mesh (125 Microns)
  • Max. Particle Size: .018″ / .457 mm
  • ฯperating Temp Without Local Computer or With Remote Computer: -40 to 250°F (-40 to 121°C) [Opt’l]
  • Extended Flow Range: 50 – 75 GPM (190 – 284 LPM)<br>[Accuracy of the extended flow range declines and is not guaranteed]<br>Overranging damages meter and voids warranty
  • Maximum Viscosity: 100 cps<br>[For viscous fluids like oils, the temperature must not fluctuate more than ±5°F to avoid accuracy fluctuations]