- Can be programmed by the infrared keypad without opening the cover
- High turndown ratio of flow rate
- Multiple flange types are available, such as ANSI, DIN, JIS, etc.
- Excellent for high-pressure applications
- Simple for installation, commission and maintenance
- Self-diagnostic capabilities, cable faults, pipe vibration
- High accuracy of +/-0.2% of reading (or +/-0.1% of reading)
- With forward / reverse flow rate measurement function
- Large-screen LCD display for easy viewing and operation on-site
| ensor Type | : | U tube (2-40 mm) / V tube (50-150 mm) |
| Size | : | 2-150 mm (1/12″-6″) |
| Flow Range | : | 0-160 kg/hr~0-580000 kg/hr |
| Accuracy | : | +/-0.2% +/-ZS of reading (Standard) |
| : | +/-0.1% +/-ZS of reading (Option) | |
| Repeatability | : | +/-0.03% +/-ZS of reading |
| Density Range | : | 200-3000 kgf/m3 (0.2-3.0 g/cm3) |
| Accuracy | : | +/-0.002 g/cm3 |
| Temperature Range | : | -50~125 °C (Standard) |
| : | -50~350 °C (Option, Remote Only) | |
| Ambient Temperature | : | -40~60 °C |
| Max. Pressure | : | 100 kgf/cm2 |
| Material | ||
| Wetted Parts & Flange | : | S.S. 316L, Hastelloy C22 |
| Sensor Housing | : | Stainless Steel 304 |
| Junction Box | : | Aluminum Alloy (Epoxy Paint) |
| Process Connection | : | Flange |
| Flange Type | : | JIS 10K / JIS 20K / JIS 40K |
| : | ANSI 150# / ANSI 300# / ANSI 600# | |
| : | DIN PN10 / PN16 / PN25 / PN40 | |
| Protection Class | : | IP67 |
| : | Explosion Proof, Ex d eb [ib] IIC T6 (Option) | |
| Signal Cable Length | : | 10-150 m |
| Display | : | 4 lines LCD with illumination |
| Flow Rate Unit | : | g/s, kg/m, kg/hr, t/hr, lb/m, gal/m… (8 Digits) |
| Density Unit | : | kg/m3, g/cm3, lb/Usgal (5 Digits) |
| Totalizer Unit | : | g,kg,T,L,m3,Nm3,lb,gal,lb,ft3…(11 Digits) |
| Temperature | : | °C, °F (6 Digits) |
| Keypad | : | Infrared light sensor, can be programmed |
| without opening the cover | ||
| Turndown Ratio | : | 40:1 |
| Damping | : | 0.0-1.0 Seconds |
| Low Flow Cutoff | : | 0.0-3600 t/hr and 0.0-3,600,000 m3/hr |
| Communication | : | RS485 (Modbus Protocol) (Standard) |
| : | HART Signal (Option) | |
| Current Output | : | 4-20 mA(Isolated), Max. 2 channels(Option) |
| Load | : | Max. 550 W |
| Output Unit | : | Mass / Volume / Density / Temperature |
| Pulse Output | : | Active Pulse (Open Collector) |
| Rating | : | 24 VDC, 50 mA Max. |
| Display Orientation | : | 0° or 180° (Parameter Setting) |
| Power Supply | : | 90-260 VAC, 50/60 Hz or 24 VDC +/-10% |
| Power Consumption | : | 7-13 W |
| Cable Entry | : | Sensor to Converter-3/4″ G |
| : | Signal Output / Power Supply-M20 | |
| Installation | : | Compact or Remote |
ต้องการใบเสนอราคา