GENERAL SPECIFICATIONS
| Excitation | : | DC pulsed |
| Display | : | 3 Lines of LCD |
| Page 1 / Line 1 | : | 5-Digit flowrate |
| Page 1 / Line 2 | : | 11-Digit forward totalizer |
| Page 1 / Line 3 | : | Flow Percentage |
| Page 2 / Line 1 | : | 11-Digit totalizer |
| Page 2 / Line 2 | : | 11-Digit reverse totalizer |
| Page 2 / Line 3 | : | Display instantaneous velocity |
| Page 3 | : | Alarm |
| Flow Unit | : | m3/hr, m3/min, m3/sec, L/hr, L/min |
| GPH, GPM, GPS, mL/hr, mL/min, mL/s | ||
| Totalizer Unit | : | m3, Gallon, Liter, mL |
| Measuring Range | : | Min. 0-0.15 m/s |
| : | Max. 0-15.0 m/s | |
| Accuracy | : | +/-0.3% of reading (Velocity≥0.5 m/s) |
| : | +/-0.0015 m/s (Velocity<0.5 m/s) | |
| Repeatability | : | +/-0.05% of reading |
| Pulse Output | : | Open collector |
| Load | : | 3-30 VDC, Max. 20 mA |
| Pulse Rate | : | 1)Scaled pulse (Liter / Pulse, other) |
| : | 2)Frequency: 1-5000 Hz | |
| Keypad | : | 4 Control keys to change parameters |
| and switch display interface | ||
| Damping | : | 0.1-99.9 s |
| Data Storage | : | Operation parameters and totalizer are |
| stored by EEPROM for more than 10 years |
| Low Flow Cutoff | : | 0-9.9% |
| Self Diagnosis | : | The following error messages |
| are displayed if failure occurs | ||
| – Coil failure | ||
| – Power failure | ||
| – Overranged output | ||
| – Internal error | ||
| – Overflow | ||
| – Empty pipe | ||
| Cable Entry | : | Standard: PG11 Option: 1/2″ NPTF |
| Protection Class | : | IP67 |
| : | IP68 (Submersible) | |
| Ambient Temp. | : | -25~65 °C |
| Housing Material | : | Aluminum alloy |
| Power Supply | : | 3.6 V battery, Size D |
| Battery Life | : | 2-3 Years |
| Determined by size & function | ||
| Communication Protocol | : | RS485 (MODBUS protocol) |
| Weight | : | 2.0 kg (Compact) |
| 4.3 kg (Remote) | ||
| Mounting | : | Wall mounting |
| Bracket on 2″ pipe | ||
| Compact version (Installed on sensor) |