AMC3200E Series

Electromagnetic flow meter

The ALIAMAG AMC3200E Series is a heat meter converter of an electromagnetic flowmeter that can be paired with any of ALIA AMF series sensors. The unit features multiple display parameters, including flow rate, energy, flow total, energy total, supply temperature, return temperature, diagnostic, programming and troubleshooting. It is equipped with MODBUS, Bluetooth and BACnet protocol.

FEATURES

  • Four line LCD display Flow Rate / Energy / Totalizer / Temperature
  • +/-0.2% value of reading
  • Bi-direction flow measurement, and the display can rotate
  • With query functions for hourly report, daily report, monthly report
  • query function
  • 99 times / dates records for alarm
  • 99 (total) times records for power on / off
  • MODBUS, Bluetooth, BACnet protocol

PRODUCT ATTACHMENTS

DATASHEET

ติดต่อขอรายละเอียดหรือสนใจสินค้า

  • Line : @intech2000
  • Email : intech@intech2000.com
  • Tel : 02-440-1853
Category: Brand:

GENERAL SPECIFICATIONS

Excitation : DC Plused
Display : 4 Lines LCD with backlight
Line 1 : Date and Time
Line 2 : 5 Digit flowrate
6 Digit energy value
Error code
Supply temperature
Line 3 : 9 Digit totalizer for forward flow / reverse flow
9 Digit totalizer for heat / cold energy
Error code content
Return temperature
Line 4 : Differential temperature
Unit : L/s, L/min, L/hr, m3/s, m3/min, m3/hr,
mL/hr, mL/min, mL/s, kW, MW, KJ/hr,
MJ/hr, GJ/hr, Mcal/hr, Kcal/hr, Cal/hr, BTU/hr
Measuring Range : Min. 0-0.15 m/s
: Max. 0-15 m/s
Accuracy : +/-0.2% of reading (Velocity0.5 m/s)
: +/-0.001 m/s (Velocity<0.5 m/s)
Repeatability : +/-0.05% of reading
Current Output : 4-20 mA (Isolated)
Load : Max. 600 Ω
Pulse Output : Open collector
Rating : 3-30 VDC, 50 mA Max.
Pulse Rate : 1) Scaled pulse, (L/Pulse, Other)
: 2) Frequency: 0-5000 Hz
Communication : Bluetooth (Apply to Android System)
RS485 (MODBUS Protocol) / BACnet
Keypad : 3 External keys for programming
and display control
Low Flow Cutoff : 0-9.9%
Data Logger Function : 99 Date / time records for alarm
Record Data : Date / time of power on/ off
: 99 Years flow rate / energy /
temperature / total flow / total energy
Record data every one hour
Damping : 0.1-99.9 s
Self Diagnosis : The following error messages are
displayed if failure occurs
– Temperature failure
– Temperature abnormal
– Empty pipe
– EEPROM abnormal
Data Storage : Operation parameters and totalizer
figures are stored by EEPROM for more
than 10 years
Cable Entry : Standard: M20  Option: 1/2″ NPTF
Protection Class : IP67
Ambient Temperature : -25-65 °C
Material : Aluminum Alloy
Temperature Input : PT1000, 2 wires
Power Supply : 90-260 VAC, 50/60 Hz
: 24 VDC +/-10% (Option)
Power Consumption : 10-20 W (Dependent on sensor size)
Weight : 4.5 kg
Mounting : Bracket on 2″ pipe
etc