| General Specifications | |
|---|---|
| Spec Name: | Description: |
| Electronics Enclosure | NEMA4X (IP 66) polycarbonate with clear, shatterproof cover |
| Accuracy | ±0.25% of Range or 2 mm (0.8 in) whichever is greater. Repeatability & Linearity: ±0.1% |
| Display | White, backlit matrix – displays flow rate, totalizer, relay status, operating mode, and calibration menu |
| Programming | Built-in 5-key calibrator with English, French, or Spanish language selection |
| Power Input | 100-240 V AC 50/60 Hz, see Options. 10 VA max depending on options |
| Output | Isolated 4-20mA / 0-5 V, 1000 ohms load maximum |
| Control Relays | 2 Relays, form ‘C’ dry contacts rated 5 amp SPDT; programmable level alarm, pump control, pump alternation, failsafe/echo-loss, air temperature alarm |
| Electrical Surge Protection | Sensor, 4-20mA and, AC power input |
| Data Logger | Built-in 26 million point data logger with a USB output and Windows software |
| Operating Temperature (Electronics) | -20 °C to 60 °C (-5 °F to 140 °F) |
| Approximate Shipping Weight | 4.5 kg (10 lbs) |
| Sensor Specifications | |
|---|---|
| Spec Name: | Description: |
| Maximum Range | 4.57 m (15 ft) with standard PZ15 sensor 10 m (32 ft) with standard PZ32T sensor |
| Deadband (Blanking) | Programmable, Minimum 203.2 mm (8 in) |
| Beam Angle | 8° |
| Operating Frequency | PZ15: 92 kHz PZ32T: 42 kHz |
| Exposed Materials | PZ15: PVC PZ32T: PVC and Teflon |
| Operating Temperature | -40 °C to 65 °C (-40 °F to 150 °F) with automatic temperature compensation |
| Submersion Rating | Protected for accidental submersion to 3 m (10 ft) maximum |
| Sensor Cables | RG62AU coaxial, 7.6 m (25 ft) standard length, see Options |